Membrane Type: Spiral
Type: RO
Salt Rejection: 99.3%
Flux: 11500 GDP
Size: 8 Inch
Lifespan: 2-3 Year
Customization:
Diamond Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory
  • Overview
  • Product Description
  • Company Profile
Overview

Basic Info.

Model NO.
ULP8040-400
Maximum Operating Pressure
600 Psi
Maximum Operating Temperature
45ºC
Maximum Feed SDI(SDI15)
5.0
Transport Package
Standard Export Package
Specification
110cm× 26cm× 22cm
Trademark
UltraClean or Customized
Origin
China
HS Code
8421999090
Production Capacity
150000PCS/Year

Product Description

UltraClean ULP series membrane elements are suitable for desalination treatment of water sources such as surface water, groundwater, tap water and municipal water with a salt content below about 2000ppm. They are mainly used in various scales of pure water, boiler feed water, food processing and pharmaceutical manufacturing industries In a variety of fields, it can achieve the same high water flux and high salt rejection as conventional low pressure membranes under ultra-low operating pressure conditions. Its operating pressure is about 2/3 of the operating pressure of conventional low-pressure composite membranes, and the desalination rate can reach 99.3%, thereby reducing the investment costs of related pumps, pipelines, containers and other equipment and the operating costs of the reverse osmosis system, increasing the economic benefits.


Product  Highlights

1.Stable membrane performance and high organic removal rate
2.Meet the near-zero discharge standard of industrial wastewater
3.Low operating pressure, taking into account high water production and operating costs


Membrane Specification

8040 Low Presussure Reverse Osmosis Membrane for RO Water Treatment System Best Quality

 
A inch(mm) B inch(mm) C inch(mm)
40 (1016) 1.125 (19) 7.9 (201)


Performance Specification
 
Effective Membrane Area
ft²(m²)
Stablized Rejection
Rate(%)
Minimum Rejection
rate(%)
Flux
gpd(/d)
400 (37) 99.3 99.0 11500 (43.5)

Test conditions: inlet pressure 1.03 MPa (150 psi); inlet temperature 25°C (77°F); inlet water quality 1500ppm NaCl; inlet pH 8; recovery 15%.



Operating and Cleaning Limits
 
Maximum operating temperature                                                                                                                                                                                         113 ºF (45ºC)
Maximum operating pressure                                                                                                                                      600 psi (41 bar)
Maximum pressure drop                                                                                                                                                                                                        15 psi (1.0 bar)
pH range
Continuous operation                                                                                                                                                                              2 - 11
Short cleaning (30 minutes)                                                                                                                                                                                                                     1 - 13
Maximum Influent Sludge Density Index SDI                                                                                                                                             5
Free chlorine tolerance                                                                                                                                                                   < 0.1 ppm

Permeate flow for individual elements may vary ±15 percent from the value specifed.
Active membrane area guaranteed ±4%.
Stabilized salt rejection is generally achieved within 24-48 hours of continuous use; depending upon feedwater characteristics and operating conditions.
Product Description

8040 Low Presussure Reverse Osmosis Membrane for RO Water Treatment System Best Quality8040 Low Presussure Reverse Osmosis Membrane for RO Water Treatment System Best Quality

Company Profile

 


About Us
8040 Low Presussure Reverse Osmosis Membrane for RO Water Treatment System Best Quality8040 Low Presussure Reverse Osmosis Membrane for RO Water Treatment System Best Quality
Why Choose UltraClean
8040 Low Presussure Reverse Osmosis Membrane for RO Water Treatment System Best Quality8040 Low Presussure Reverse Osmosis Membrane for RO Water Treatment System Best Quality

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory
Registered Capital
100000000 RMB
Plant Area
>2000 square meters