4040 RO Reverse Osmosis with High Rejection for Water Treatment

Membrane Type: Spiral
Type: RO
Salt Rejection: 99.82%
Flux: 1180 GDP
Size: 4 Inch
Lifespan: 2-3 Year
Customization:
Diamond Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
SW4040-82XHR
Maximum Operating Pressure
12000 Psi
Maximum Operating Temperature
45 ºC
Maximum Feed SDI(SDI15)
5.0
Transport Package
Standard Export Package
Specification
110cm× 26cm× 22cm
Trademark
UltraClean or Customized
Origin
China
HS Code
8421999090
Production Capacity
150000PCS/Year

Product Description

UltraClean SW series special reverse osmosis membrane element for seawater desalination is a high-end reverse osmosis membrane element. The bottom membrane of the support layer has high compression resistance and thick skin.It is dense and has no defects on the membrane surface; it is resistant to abrasion and chemical degradation; and no post-treatment is required in the manufacturing process of membrane elements. Its wide pH resistance and high cleaning efficiency, can use ordinary acid and alkali for strong and efficient cleaning, because the cleaning is more thorough, the long-term operating pressure of the membrane system is lower, and the service life is higher. It can greatly reduce operating costs and bring long-term optimal economics to seawater desalination systems.


Product  Highlights

1.High salt rejection
2.Compression resistance, contamination resistance and high cleaning efficiency
3.Improve the overall economics of the desalination system


Membrane Specification

4040 RO Reverse Osmosis with High Rejection for Water Treatment

 
A inch(mm) B inch(mm) C inch(mm)
37.9 (963) 0.75 (19) 3.9 (99)


Performance Specification
 
Effective Membrane Area
ft²(m²)
Stablized Rejection
Rate(%)
Minimum Rejection
rate(%)
Flux
gpd(/d)
82 (7.6) 99.82 99.7 1180 (4.5)

Test conditions: inlet pressure 5.5 MPa (800 psi); inlet temperature 25°C (77°F); inlet water quality 2000ppm NaCl; inlet pH 8; recovery 15%.



Operating and Cleaning Limits
 
Maximum operating temperature                                                                                                                                                                                         113 ºF (45ºC)
Maximum operating pressure                                                                                                                                    1200 psi (83 bar)
Maximum pressure drop                                                                                                                                                                                                        15 psi (1.0 bar)
pH range
Continuous operation                                                                                                                                                                              2 - 11
Short cleaning (30 minutes)                                                                                                                                                                                                                     1 - 13
Maximum Influent Sludge Density Index SDI                                                                                                                                             5
Free chlorine tolerance                                                                                                                                                                   < 0.1 ppm

Permeate flow for individual elements may vary ±15 percent from the value specifed.
Active membrane area guaranteed ±4%.
Stabilized salt rejection is generally achieved within 24-48 hours of continuous use; depending upon feedwater characteristics and operating conditions.


Production Line
4040 RO Reverse Osmosis with High Rejection for Water Treatment4040 RO Reverse Osmosis with High Rejection for Water Treatment4040 RO Reverse Osmosis with High Rejection for Water Treatment
About Us
4040 RO Reverse Osmosis with High Rejection for Water Treatment4040 RO Reverse Osmosis with High Rejection for Water Treatment
Why Choose UltraClean
4040 RO Reverse Osmosis with High Rejection for Water Treatment4040 RO Reverse Osmosis with High Rejection for Water Treatment

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory
Registered Capital
100000000 RMB
Plant Area
>2000 square meters