• 8 Inch Nanofiltration Membrane for Industrial Water Treatment System
  • 8 Inch Nanofiltration Membrane for Industrial Water Treatment System
  • 8 Inch Nanofiltration Membrane for Industrial Water Treatment System
  • 8 Inch Nanofiltration Membrane for Industrial Water Treatment System
  • 8 Inch Nanofiltration Membrane for Industrial Water Treatment System

8 Inch Nanofiltration Membrane for Industrial Water Treatment System

Membrane Type: Spiral
Type: NF
Rejection: 50-70%(Naci) ≥99%(Mgso4)
Flux: 8250 Gpd(Naci);9780 Gpd(Mgso4)
Size: 8 Inch
Lifespan: 2-3 Year
Customization:
Diamond Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
NF150-8040-400
Maximum Operating Pressure
600 Psi
Maximum Operating Temperature
45ºC
Maximum Feed Water SDI
5.0
Transport Package
Standard Export Package
Specification
110cm× 26cm× 22cm
Trademark
UltraClean or Customized
Origin
China
HS Code
8421999090
Production Capacity
150000PCS/Year

Product Description

In the preparation process of UltraClean UC NF150 series nanofiltration membrane elements, a unique formula and process are used. It is specially developed and produced for the special solute concentration and separation process, with stable and reliable performance and strong anti-pollution. It fills the blank range of molecular weight cutoff of existing nanofiltration membranes. It is suitable for separation of fine materials, removal of TOC and THM precursors, salt separation of monovalent and multivalent ions, decolorization, separation and concentration of small molecular organics, etc.


Product  Highlights

1.Fill in the blank range of molecular weight cut-off of existing nanofiltration membranes
2.Suitable for separation of fine materials, separation and decolorization of small molecular organic substances, and salt separation of monovalent and multivalent ions
3.Stable chemical properties, strong anti-pollution


Membrane Specification

8 Inch Nanofiltration Membrane for Industrial Water Treatment System
 
A inch(mm) B inch(mm) C inch(mm)
40 (1016) 1.125 (29) 7.9 (201)


Performance Specification
 
Effective Membrane Area
ft²(m²)
Stablized Rejection
Rate(%)
Flux
gpd(/d)
82(7.6) 50-70%(NaCI)
≥99%(MgSO4)
8,250 (31.2) NaCI
9,780 (36.8) MgSO4
 
Test conditions: inlet pressure 0.48 MPa (70 psi); inlet temperature 25°C (77°F); inlet water quality 2000ppm NaCl, 2,000 ppm MgSO4 inlet pH 8; recovery 15%.


Operating and Cleaning Limits
 
Maximum operating temperature                                                                                                                                                                                  113 ºF (45ºC)
Maximum operating pressure                                                                                                                                600 psi (41 bar)
Maximum pressure drop                                                                                                                                                                                                 15 psi (1.0 bar)
pH range
Continuous operation                                                                                                                                                                                                                              2 - 11
Short cleaning (30 minutes)                                                                                                                                                                                                                 1 - 13
Maximum Influent Sludge Density Index SDI                                                                                                                                                                                    5
Free chlorine tolerance                                                                                                                                                                                                                 < 0.1 ppm

Permeate flow for individual elements may vary ±15 percent from the value specifed.
Active membrane area guaranteed ±4%.
Stabilized salt rejection is generally achieved within 24-48 hours of continuous use; depending upon feedwater characteristics and operating conditions.


8 Inch Nanofiltration Membrane for Industrial Water Treatment System8 Inch Nanofiltration Membrane for Industrial Water Treatment System

About Us
8 Inch Nanofiltration Membrane for Industrial Water Treatment System8 Inch Nanofiltration Membrane for Industrial Water Treatment System
Production Line
8 Inch Nanofiltration Membrane for Industrial Water Treatment System
Why Choose UltraClean
8 Inch Nanofiltration Membrane for Industrial Water Treatment System8 Inch Nanofiltration Membrane for Industrial Water Treatment System

Delivery Package
8 Inch Nanofiltration Membrane for Industrial Water Treatment System

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now